Limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter

This thesis is submitted in partial fulfilment of the requirements for the degree of Master of Science in Electrical and Electronic Engineering, 2022.

Détails bibliographiques
Auteur principal: Thapaliya, Sudeep
Autres auteurs: Rahim, Abu Hamed M. Abdur
Format: Thèse
Langue:English
Publié: Brac University 2024
Sujets:
Accès en ligne:http://hdl.handle.net/10361/24163
id 10361-24163
record_format dspace
spelling 10361-241632024-09-23T21:02:39Z Limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter Thapaliya, Sudeep Rahim, Abu Hamed M. Abdur Department of Electrical and Electronic Engineering, Brac University DFIG LVRT SDBR RSFCL LRFCL FLC-SDBR This thesis is submitted in partial fulfilment of the requirements for the degree of Master of Science in Electrical and Electronic Engineering, 2022. Cataloged from PDF version of the thesis. Includes bibliographical references (pages 69-82). A doubly fed induction generator (DFIG) is preferred over other wind generators because of its capacity to adapt to variable wind speeds and economic converter. DFIG is sensitive to grid faults as its stator is directly connected to the grid. To fulfill the grid code requirement, DFIG is required to be connected to the grid during the fault. Converter control is not sufficient to maintain grid stability. Ladder resistive fault current limiter (LRFCL) and fuzzy logic control-based series dynamic braking resistor (FLC-SDBR) are proposed for low voltage ride-through (LVRT) enhancement. The series resistor consumes the surplus active power during the grid voltage dip. A control system has been developed to control the step resistance in the LRFCL, whose operation changes with the deviation in grid voltage. A fuzzy logic-based control system has been developed to precisely control the power being consumed in the SDBR. The LVRT capability of the DFIG has been investigated for different levels of fault in bus terminals. The performance of the proposed model is compared with that of a resistive superconducting fault current limiter (R-SFCL) and a conventionally controlled SDBR. Simulation results performed in MATLAB show that the proposed model has the capacity to enhance LVRT for different levels of bus voltage sag. FLC-SDBR is superior in performance with a quick restoration of the system stability. Sudeep Thapaliya M. Electrical and Electronic Engineering 2024-09-23T05:28:52Z 2024-09-23T05:28:52Z 2022 2022-08 Thesis ID 20261009 http://hdl.handle.net/10361/24163 en Brac University theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. 84 pages application/pdf Brac University
institution Brac University
collection Institutional Repository
language English
topic DFIG
LVRT
SDBR
RSFCL
LRFCL
FLC-SDBR
spellingShingle DFIG
LVRT
SDBR
RSFCL
LRFCL
FLC-SDBR
Thapaliya, Sudeep
Limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter
description This thesis is submitted in partial fulfilment of the requirements for the degree of Master of Science in Electrical and Electronic Engineering, 2022.
author2 Rahim, Abu Hamed M. Abdur
author_facet Rahim, Abu Hamed M. Abdur
Thapaliya, Sudeep
format Thesis
author Thapaliya, Sudeep
author_sort Thapaliya, Sudeep
title Limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter
title_short Limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter
title_full Limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter
title_fullStr Limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter
title_full_unstemmed Limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter
title_sort limiting the fault current of a wind turbine driven doubly fed induction generator system using fuzzy resistance limiter
publisher Brac University
publishDate 2024
url http://hdl.handle.net/10361/24163
work_keys_str_mv AT thapaliyasudeep limitingthefaultcurrentofawindturbinedrivendoublyfedinductiongeneratorsystemusingfuzzyresistancelimiter
_version_ 1814308344699027456